Re: mituple ip problem

From: Henrik Nordstrom <hno@dont-contact.us>
Date: Fri, 09 Oct 1998 07:02:19 +0200

commandomail wrote:
>
> my RH 5.1 installed 2 NIC with 2 IP binding , one is 192.168.0.x ( in
> Intranet ) another is 202.102.x.x (Internet), but squid seems only bind
> to 202.102.x.x, it do not response to the request from 192.168.0.x.
> what's the matter ?

Have you set XXX_incoming_address in squid.conf? If you have then it
only listens on that address.

If you haven't set XXX_incoming_address then Squid should listen on all
available interfaces.

(XXX == tcp and udp. See squid.conf)

---
Henrik Nordström
Spare time Squid Hacker
Received on Fri Oct 09 1998 - 02:23:34 MDT